FREE 24-hour Tech Support: 724-746-5500
blackbox.com
© 2007. All rights reserved. Black Box Corporation.
Modem 202 and Modem 202T
Reliable old favorites, manufactured
to today’s exacting specifications.
generate a data pattern from the locally attached DTE or have
the modem generate a test pattern.
TECH SPECS
MD845A-R2:
You can also run line and modem tests to verify the integrity
of the line between the local and remote modems. With this
test, the local Modem 202T loops back received data to the
transmitter and sends the data to the remote modem. These
characters can be done by using a modem test pattern or by
originating a data pattern from the local DTE.
Distance (Maximum) — 20 mi. (32.2 km) on unloaded lines,
depending upon line characteristics
Enclosure — Standard NEMA 1; 18-gauge steel with mounting flanges
Handshake Modes — DataSense (DSCC) or RTS line
1
Mounting — Hole pattern ⁄4" (0.6-cm) diameter located on rectangle
8.3" x 2.8" (21.1 x 7.1 cm)
Operating Frequency — 1200/2200 Hz (Bell 202 or 1300/2100 ITU V.35)
FSK (Frequency Shift Key)
Operation — 2-wire, half-duplex or 4-wire, full duplex
Protocol — Asynchronous
Speed — 300, 600, or 1200 baud half- or full duplex up to
1200 baud simplex
Configuration is simple!
To configure the Modem 202T, just set a few DIP switches.
These jumper settings control operating characteristics such
as the dynamic range of the modem receiver, the transmit level,
and the call turnaround squelch (which guards against echoes
from already-completed transmissions).
Connectors — (2) terminal blocks, (1) DB9 F
Indicators — (4) LEDs: Data Out, Data In, Carrier, Power
Temperature Tolerance — -4 to +158°F (-20 to +70°C)
Power — Input: 11 to 18 volts DC at a minimum of 200 mA;
External wallmount power supply provided for 110 VAC nominal
Size — 1.5"H x 5"W x 9"D (3.8 x 12.7 x 22.9 cm) over mounting flanges
MD845A-R2
By default, the Modem 202T’s DIP switches are set for 4-wire,
full duplex operation. To reconfigure the modem for 2-wire, half-
duplex applications, just change the jumper settings.
When configured for 4-wire, full duplex operation, the
modem can be strapped to transmit data to corresponding slave
modems with no RTS to Carrier Turnoff Signal (CTS) delay, which
is ideal for minimizing turnaround. To increase the modem’s
turnaround time, just configure it for 2-wire, half-duplex
operation. This will enable the modem to encounter an RTS-to-
CTS delay when transmitting to its slave modems.
MD1970A and MD1970A-DC:
Carrier Detect Delay — 6 or 23 ms OFF-to-ON, 6 ON-to-OFF
Carrier Frequencies — Mark: 1200 Hz 1%;
Space: 2200 Hz 1%
Diagnostics — Self-test, analog loopback, digital loopback,
test pattern transmit
Line Impedance — 600 ohms 10% transformer coupled
and transient protected
Modulation — Phase coherent; frequency shift keyed (FSK)
Operation — 2-wire, half-duplex or 4-wire, full duplex
Protocol — Asynchronous
RTS to CTS Delay — 8, 33, 59, or 219 ms
Speed (Maximum) — Unconditioned line: 1200 bps;
Conditioned line: 1800 bps
Transmitter Output Level — Selectable from 0 to -14 dBm in 2-dB steps
Turnaround Squelch — 8 ms or 159 ms
Connectors — (1) DB25 female (DTE); (1) RJ-45 (telco)
Indicators — (7) LEDs: RS, CS, CD, RD, TD, TM, Power
Temperature Tolerance — -40 to +185°F (-40 to +85ºC)
Humidity Tolerance — Up to 95%, noncondensing
Power — MD1970A: 115 VAC, 60 Hz;
On the inside of the Modem 202T is a simple three-position
header for full or half-duplex mode. The device’s DCE interface
quickly connects to any device equipped with a standard DB9
or DB25 connector.
Troubleshooting’s easy, too.
An LED control display enables you to confirm modem
operation at a glance, and a local and remote test switch
enables verification of the link’s integrity.
Along with the Modem 202 or Modem 202T, you’ll receive
a cable for making RJ-45 to 4-wire leased-line connections.
But to connect a data terminal, you’ll need an RS-232 cable.
MD1970A-DC: 12 to 60 VDC
Size — 2.3"H x 7"W x 9.6"D (5.8 x 17.8 x 24.4 cm)
WHAT‘S INCLUDED
MD845A-R2, MD1970A, MD1970A-DC:
Item
Code
✦
✦
✦
Modem
Modem 202 (without Diagnostics)
Modem 202T Standalone (with Diagnostics)
Standalone
MD845A-R2
RJ-45 to 4-wire leased-line cable
User‘s manual
AC
DC
MD1970A
MD1970A-DC
MD1970C
MD1970C:
✦
✦
202T Modem Rackmount Card
User‘s manual
Rackmount Card
You may also need…
DB9 Extension Cable
DB9 Male to DB25 Female Adapter
EDN12H-0010-MF
FA521A-R3
8/22/2007
#16407
724-746-5500
blackbox.com
3 of 3
|
Billion Electric Company Network Card BiGuard 50G User Manual
Billy Goat Chipper TKD502SP User Manual
Black Decker Coffeemaker DCME10 User Manual
Blanco Indoor Furnishings 501 119 12 User Manual
Boss Audio Systems Car Stereo System CCR612 User Manual
Campbell Hausfeld Air Compressor FP260100 User Manual
Canon Film Camera EOS 1000 F User Manual
Casio Clock Radio SF 3990 User Manual
Cisco Systems IP Phone OL 19470 01 User Manual
Cisco Systems IP Phone OL 23092 01 User Manual